WaveWare Button Programming Guide
What You Can Edit with Button Programming
- Frequency: Between 450 – 470 MHz
- Cap Code(s): Up to 7 Cap Codes
- Baud Rate: 512, 1200 and 2400
- Password: Protection of the Configuration
Button Overview
- The Function Button (red dot):
- Moves you to the next step/screen
- Allows the viewing of each individual screen
- The Read / On Button (blue dash):
- Pressing this at anytime exits program mode
- Returns you to the version screen
- The 4 arrow buttons (Up, Down, Backward and Forward)
- Allows the changing of the location and values of the cursor
To start, be sure the pager is TURNED-OFF:
- To do this, press the Function Button (red dot)
- Then scroll from left to right until the “Pager OFF” icon
- Press the Red Dot Button 1 time and it will ask to be sure
- Press the Red Dot Button again to confirm
- The Pager will display “PAGER OFF”
- Press and hold BOTH the Function Button (Red Dot), and press and hold the Read / On Button (Blue Dash)
- This will place pager into “Test Mode”
- Once in Test Mode, Firmware Version is displayed
- Along with date and time to enter program mode press the Function Button (Red Dot)
- This takes you to the password screen



Pager Overview Continued
Changing the Password
- The Pager default password is all zero’s (000000)
- Password can be edited by using the arrow buttons
- The Left / Right arrows moves the cursor across the screen
- The Up / Down arrows changes the highlighted numeric value
- When complete, press the red dot button
The Pager Frequency
- This can be VHF or UHF, dependent on the pager
- Must be entered without a dot (.)
- Example: 467800000 is correct ( But 467.800000 is NOT )
- Frequency is edited by using the arrow buttons
- The Left / Right arrows moves the cursor across the screen
- The Up / Down arrows changes the highlighted numeric value
- When complete, press the red dot button
The Pager Baud Rate:
- PalCare only uses 512 Baud
- Baud Rate is edited by using the arrow buttons
- The Left / Right arrows moves the cursor across the screen
- The Up / Down arrows changes the highlighted numeric value
- When complete, press the red dot button
The Pager Cap Code(s):
- This is a 7-Digit numeric number
- This number is dependent on the group
- Must be entered with all leading zeros required to complete
- Example: The Cap Code can be: 0220001, 0220002, 0220003, etc.
- Baud Rate is edited by using the arrow buttons
- The Left / Right arrows moves the cursor across the screen
- The Up / Down arrows changes the highlighted numeric value
- If other cap codes to enter, press red dot button and repeat